2 General Description
- Incoming fragments may be of fixed size or of variable size depending on the sub-detector.
- Incoming fragments contain flags which may be set if the ROD or front-end detects errors in the data before transmission to the ROB.
- The Read-out Link between the ROD and the ROB is duplex, i.e. the ROB can send flow control and other signals back to the ROD.
- The Level-2 Trigger and Level-3 Trigger can function if one or more ROBs do not respond to signals from them (e.g. RoI_request, L2_accept).
- Front-end systems must preserve the trigger order at the input to the ROB. Each front-end must provide exactly one fragment for each trigger. A front-end must not ignore a trigger and must send a fragment (even if it is a null fragment).
- Event_ID numbers will increment monotonically (i.e. they will not be random).
- Header or trailer information in event fragments will not be compressed by the Front -End before transmission to the ROB.
- Fragments will contain a start_of_event marker.
Issue: 2.0 - Revision: 0 - Last Modified: 18 June 1996